Warehouse display
Description
The Major Tech MT1887 combines a 1,500 V DC measuring range with True RMS AC measurement, Bluetooth transfer and an IP67 enclosure. It suits solar and industrial fault-finding work that needs more DC voltage range than a standard 1,000 V meter.
Its 4–20 mA percentage function also helps with process-loop checks, while the 40,000-count display provides detailed readings.
Why you’ll love it
- Handle solar DC checks: Measure up to 1,500 V DC with correctly rated leads.
- Share readings: Transfer measurement data to a compatible mobile app.
- Check instrumentation: Display current as a percentage of a 4–20 mA loop.
- Work on site: IP67 protection and rubber moulding support field use.
MT1887 IP67 protection demonstration
Features
- 40 000 count with 41 Segment Bargraph
- Measures DCV to 1500V & ACV up to 1000V
- Temperature measurement from -50⁰C to 1000⁰C
- AC & DC Micro Amps up to 10A
- 4-20mA% process loop measurements with % reading
- Capacitance to 40mF
- Frequency to 100MHz
- Duty Cycle
- Relative mode
- Automatic NCV where LCD backlight turns red
- Min, Max and Data Hold
- Auto Power Off
- IP67 Dust & Waterproof
Technical specifications
Resolution and accuracy depend on the selected range and test conditions. Summary values below are from the manufacturer; refer to the linked user manual for full range-specific limits.
| Function | Range | Resolution | Accuracy |
|---|---|---|---|
| DC voltage | 0.1mV - 1500V | 0.1mV | ± (0.1% + 6 Digits) |
| AC voltage | 0.1mV - 1000V | 0.1mV | ± (1% + 8 Digits) |
| DC Current | 0.01μA - 10A | 0.01μA | ± (1.0% + 3 Digits) |
| AC Current | 0.1μA - 10A | 0.1μA | ± (1.5% + 8 Digits) |
| Duty Cycle | 5.0% to 95.0% | 0,01% | ± (1.2% + 2 Digits) |
| Resistance | Up to 40 MΩ | 0.01 Ω finest | ±(0.5% + 8 digits) to ±(2.0% + 10 digits), range-dependent |
| Frequency | Up to 100 MHz | 0.001 Hz finest | Range-dependent; 100 MHz accuracy not specified in manual |
| 4-20mA% | 25% to 125% | 0,01% | ± (50 Digits) |
| Capacitance | Up to 40 mF | 0.01 nF finest | Range-dependent; 40 mF accuracy not specified in manual |
| Temperature | −50 to 1,000°C | 1°C | ±(1.0% of reading + 2.5°C), excluding probe error |
| True RMS Measurements | Yes | ||
| AC Bandwidth | 50Hz to 1000Hz | ||
| Digital Display | 40 000 | ||
| Bargraph | Yes | ||
| Bluetooth | Yes | ||
| Continuity | Yes | ||
| Diode test | Yes | ||
| Non-Contact Voltage (NCV) | Yes | ||
| Overrange indication | Yes | ||
| Input impedance | >10MΩ VDC & >3MΩ VAC | ||
| Min Max | Yes | ||
| Peak hold | >1mS | ||
| Data Hold | Yes | ||
| Enclosure | Double moulded waterproof IP67 | ||
| Low battery indication | Yes | ||
| Power source | 6LR61 | ||
| Weight | 342g | ||
| Dimensions | 187 x 81 x 50mm | ||
| Safety Specs | CAT IV 600 V / CAT III 1,000 V, per user manual | ||
The 1,500 V DC measurement range does not extend the stated measurement-category voltage ratings.
Included accessories
- Type-K Temperature Probe
- Type-K Adaptor
- Test Leads
- 9V Battery
- Instruction Manual