MAJOR TECH MT994 Multifunction Process Calibrator with RTD & Thermocouple Simulation

MAJOR TECH (PTY) LTDSKU: MJ004/MT994

Price:
Sale priceN$5,708.70

Tax included

Warehouse display

Description

The Major Tech MT994 brings loop testing and temperature-sensor simulation into one compact instrument. Its two independent channels support applying a process signal while observing the response during commissioning or maintenance.

It adds Pt100, Cu50 and thermocouple simulation to current, voltage and pulse functions, making it useful when a job extends beyond standard 4–20 mA loops.

Why you’ll love it

  • Cover more instruments: Simulate temperature sensors as well as loop signals.
  • Check input and output: Two independent channels help trace signal paths.
  • Set test signals: Adjustable outputs support transmitter and valve checks.
  • Follow a trend: View changing signals on the colour screen.

Features

  • Active current output: range: 0~24mA
  • Maximum load: 750Ω
  • Passive current output: range: 0-24 mA
  • External power supply up to 30V
  • Voltage output: range: 0-24 V
  • Maximum current 30mA
  • 24V voltage output
  • Drive current: 24mA
  • In addition, there is XMT Passive Current Signal, plus RTD simulation with Pt100, cu50 thermal resistance and 10 kinds of thermocouple
  • Current input measurement: range: 0-24 mA Input impedance:100Ω
  • Voltage input measurement: range: 0-30 V Input impedance: 2MΩ
  • Real-time Curve: The changing trend of input and output signals can be displayed by drawing a curve, and the sampling time of the curve can be set.
  • It can also automatically adjust the display curve within the range of maximum and minimum values in a certain period
  • PWM output (frequency): Range: 0-9999Hz
  • The high-definition 240*320 TFT colour LCD screen ensures readings are easily viewed
  • Built-in lithium rechargeable 3000mAh battery power supply with standby time of around 26 hours; the using time varies, based on the usage (It can be 8-10 hours with 20mA continuous output)

Technical specifications

Resolution and accuracy depend on the selected range and test conditions. Summary values below are from the manufacturer; refer to the linked user manual for full range-specific limits.

Function Range Resolution Accuracy
Current 0 to 24mA 0.001mA ± (0.02% + 0.003)
Voltage 0 to 24V 0.001V ± (0.02% + 0.003)
Passive 0 to 24mA 0.001mA ± (0.02% + 0.003)
24V Loop 0 to 24mA 0.01mA ± (0.1% + 0.005)
Frequency Output 0 to 9999Hz 5 digits ± (2%)
Milli-voltage −10 to 100 mV 0.01 mV ±(0.03% + 0.03)
Thermocouple (TC-S) 0 to 1760°C 1°C ± (0.2% + 1)
Thermocouple (TC-B) 0 to 1810°C 1°C ± (0.5% + 1)
Thermocouple (TC-E) 0 to 990°C 1°C ± (0.2% + 1)
Thermocouple (TC-K) 0 to 1320°C 1°C ± (0.2% + 1)
Thermocouple (TC-R) 0 to 1760°C 1°C ± (0.3% + 1)
Thermocouple (TC-J) 0 to 1190°C 1°C ± (0.3% + 1)
Thermocouple (TC-T) 0 to 390°C 1°C ± (0.2% + 1)
Thermocouple (TC-N) 0 to 1290°C 1°C ± (0.2% + 1)
Thermocouple (WRe3/25) 0 to 2320°C 1°C ± (0.2% + 1)
Thermocouple (WRe5/26) 0 to 2320°C 1°C ± (0.2% + 1)
Resistance 0 to 390Ω 0.1Ω ± (0.2% + 1)
PT100 -200 to 650°C 0.1°C ± (0.5% + 1)
CU50 -20 to 150°C 0.1°C ± (0.5% + 1)

Included accessories

  • Alligator Test Clips
  • Charger and Charging Cable
  • Instruction Manual

Downloads